Violation Detail
Standard Cited: 19100147 C07 III C The control of hazardous energy (lockout/tagout).
Inspection Nr: 1735740.015
Citation: 01002C
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $8,066.00
Issuance Date: 05/23/2024
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 07/31/2024
Gravity: 10
Report ID: 0521100
Contest Date:
Final Order: 06/21/2024
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/21/2024 | $8,066.00 | 07/31/2024 | Other | |
| Penalty | Z: Issued | 05/23/2024 | $0.00 | 06/24/2024 | Serious |
Text For Citation: 01 Item/Group: 002C Hazard:
29 CFR 1910.147(c)(7)(iii)(C): The retraining shall reestablish employee proficiency and introduce new or revised control methods and procedures, as necessary. On or about March 18, 2024 and thereafter, at an establishment located at 2900 East Richmond Street, in Shawano, Wisconsin; at the Laempe 150, employee(s) did not verify the electrical and pneumatic energy sources prior to performing cleaning activities on the Kloster mixer exposing employees to inadvertent startup of the equipment.