Powered by GoogleTranslate

Violation Detail

Standard Cited: 19101025 E01 I Lead.

Inspection Nr: 1727645.015

Citation: 01002C

Citation Type: Serious

Abatement Status: Abatement Completed

Initial Penalty: $0.00

Current Penalty: $0.00

Issuance Date: 08/12/2024

Nr Instances: 1

Nr Exposed: 2

Abatement Date: 12/06/2024

Gravity: 10

Report ID: 0213400

Contest Date:

Final Order: 09/05/2024

Related Event Code (REC): C

Emphasis:

Substance: 0260

Substance: 1591


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty I: Informal Settlement 09/05/2024 $0.00 12/06/2024 Serious  
Penalty Z: Issued 08/12/2024 $0.00 09/06/2024 Serious  

Text For Citation: 01 Item/Group: 002C Hazard:

29 CFR 1910.1025(e)(1)(i): For any employees exposed to lead above the permissible exposure limit for more than 30 days per year the employer did not implement engineering and work practice controls (including administrative controls) were not implemented to reduce and maintain employee exposure to lead: (a) Tactical Training Center, LLC. 10A Minneakoning Rd. Flemington, NJ 08822. On or about 2/12/2024 and thereafter, employee(s) were exposed to airborne toxic lead when employees performed weekly range maintenance duties. The employer failed to repair the disabled dust collecting unit where the bullets are stopped and collected at the back end of the firing lanes (ports); relying on the the building general ventilation. Personal exposure monitoring for airborne lead (Pb) dust was conducted by OSHA on 2/26/2024 and again on 3/09/2024 during dry sweeping of the back area of the firing lanes (ports) using broom and/or dust mop. OSHA's 2/26/2024 sampling measured employee exposure at 3.8 milligrams per cubic meter during 128 minutes of sampling, with zero exposure assumed for the balance of the 480-min work shift. Sampling on 3/09/204 measured employee exposure at 51 milligrams per cubic meter during 88 minutes of sampling, with zero exposure assumed for the balance of the 480-min work shift. These measured exposures represent 2000% and 18000% respectively of the OSHA Permissible Exposure Limit (PEL) of 0.05 milligrams per cubic meter as an 8-hour time-weighted average (TWA). Employee(s) were exposed to health hazard(s) of toxic lead (Pb) inhalation.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close