Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 1705289.015
Citation: 01002C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $11,292.00
Current Penalty: $0.00
Issuance Date: 01/29/2024
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 02/16/2024
Gravity: 10
Report ID: 0522000
Contest Date:
Final Order: 02/07/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/07/2024 | $0.00 | 02/16/2024 | Serious | |
Penalty | Z: Issued | 01/29/2024 | $11,292.00 | 02/16/2024 | Serious |
Text For Citation: 01 Item/Group: 002C Hazard:
29 CFR 1910.219(c)(2)(i): All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, excepting runways used exclusively for oiling, or running adjustments, shall be protected by a stationary casing enclosing shafting completely or by a trough enclosing sides and top or sides and bottom of shafting as location requires. a) On or about December 6, 2023, the employer did not ensure that the horizontal shafting on the Newman Trim Saw was properly guarded in that the horizontal shafting going through the enclosed gear box was unguarded. As a result, employees were exposed to caught by hazards and rotating parts.