Violation Detail
Standard Cited: 19100147 D04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1666889.015
Citation: 01002C
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/27/2023
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 10
Report ID: 0215800
Contest Date:
Final Order: 11/03/2023
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/03/2023 | $0.00 | Serious | ||
Penalty | Z: Issued | 10/27/2023 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 002C Hazard:
29 CFR 1910.147(d)(4)(i):Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a) Seneca Dairy Systems, LLC, 3236 N Hoster Road #9594, Seneca Falls, NY 13148: On or about 8/7/2023 employee did not utilize lockout devices while performing maintenance and installation of guarding on V&O Press number 292, Serial number 75-150.