Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1666286.015
Citation: 01002C
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/14/2023
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 08/09/2023
Gravity:
Report ID: 0729700
Contest Date:
Final Order: 07/28/2023
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 07/28/2023 | $0.00 | 08/09/2023 | Other | |
| Penalty | Z: Issued | 07/14/2023 | $0.00 | 08/09/2023 | Other |
Text For Citation: 01 Item/Group: 002C Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: In the CNC Area, employee(s) engaged in automated CNC machine activities were exposed to struck by, caught in, amputation, and laceration hazards in that the employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard are being followed, as the automated CNC machine had no machine specific energy control procedures for a periodic inspection to occur. The automated CNC machine is as follows: 1. Make: Emmegi; Model: Phantomatic TS Star; Designation: Centrto Di Lavoro; Serial #: C124615.