Violation Detail
Standard Cited: 19100134 F01 Respiratory Protection.
Inspection Nr: 1656517.015
Citation: 01002C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/28/2023
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 09/22/2023
Gravity: 1
Report ID: 0418100
Contest Date:
Final Order: 09/21/2023
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/21/2023 | $0.00 | 09/22/2023 | Serious | |
Penalty | Z: Issued | 08/28/2023 | $0.00 | 09/22/2023 | Serious |
Text For Citation: 01 Item/Group: 002C Hazard:
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): a) Paint Booth Area - On or about 3/09/2023, and at times prior, the employer exposed employees to respiratory hazards in that, employees required to wear a 3M tight-fitting half face respirators while painting parts for the projects when the employer failed to ensure that employees required to use 3M tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT) in the workplace.