Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1630273.015
Citation: 01002C
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/23/2023
Nr Instances: 1
Nr Exposed: 10
Abatement Date:
Gravity: 5
Report ID: 0214500
Contest Date:
Final Order: 04/13/2023
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/13/2023 | $0.00 | Serious | ||
Penalty | Z: Issued | 03/23/2023 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 002C Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees: a) At or near 10 West End Rd, Totowa NJ - Cup Forming # 8: The employer did not provide training for Thermal crew who was required to work on equipment, on or about 10/25/22