Violation Detail
Standard Cited: 19100219 E01 I Mechanical power-transmission apparatus.
Inspection Nr: 1593815.015
Citation: 01002C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/23/2022
Nr Instances: 37
Nr Exposed: 2
Abatement Date: 11/14/2022
Gravity: 10
Report ID: 0728500
Contest Date:
Final Order: 10/17/2022
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/17/2022 | $0.00 | 11/14/2022 | Serious | |
Penalty | Z: Issued | 09/23/2022 | $0.00 | 11/10/2022 | Serious |
Text For Citation: 01 Item/Group: 002C Hazard:
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt: Workplace located at 2700 W. 16th St., Sedalia, Missouri- Hallway between Lehr 5 and Lehr 6- Fans 28 & 29 and similar fans were not fully guarded shaft in which employees were required to work above the improperly guarded pulleys and shafts in order to ignite pilot lights.