Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1546939.015
Citation: 01002C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,288.00
Current Penalty: $0.00
Issuance Date: 01/11/2022
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 03/01/2022
Gravity: 10
Report ID: 0523300
Contest Date:
Final Order: 02/04/2022
Related Event Code (REC): A
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/04/2022 | $0.00 | 03/01/2022 | Serious | |
Penalty | Z: Issued | 01/11/2022 | $12,288.00 | 01/26/2022 | Serious |
Text For Citation: 01 Item/Group: 002C Hazard:
29 CFR 1910.147(c)(4)(ii)(B):The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. On or about August 4, 2021, the energy control procedure for the CFR 14-2 Grinder Machine did not include a step to ensure that stored kinetic energy had been released from the machine prior to servicing. On or about August 4, 2021, the energy control procedure for the CFR 14-2 Grinder Machine did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.