Violation Detail
Standard Cited: 19100147 C04 II D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1364702.015
Citation: 01002C
Citation Type: Serious
Abatement Date: 03/12/2020 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/23/2019
Nr Instances: 6
Nr Exposed: 60
Related Event Code (REC):
Gravity: 10
Report ID: 0418100
Contest Date:
Final Order: 06/17/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/17/2019 | $0.00 | 03/12/2020 | Serious | |
Penalty | Z: Issued | 05/23/2019 | $0.00 | 06/19/2019 | Serious |
Text For Citation: 01 Item/Group: 002C Hazard:
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control: On or about November 26, 2018, employees perform maintenance and servicing on various equipment. Employees were exposed to struck by, caught in and amputation hazards in that: a) Curing Machine - The verification step of the lockout/tagout procedure for gas, does not specify how to verify that the two gas sources were locked out. b) Curing Machine - The verification step of the lockout/tagout procedure for water, does not specify how to verify that the two water sources had been locked out. c) Curing Machine - The verification step of the lockout/ tagout procedure for steam says "right side steam 1.2Mps" this does not specify how to verify that the steam has been locked out. d) Curing Machine - The verification step of the lockout/tagout procedure for pneumatic says "listen for release of air" this does not specify how to verify that the pneumatic energy sources has been lock out.