Violation Detail
Standard Cited: 19100184 E03 II Slings.
Inspection Nr: 1295407.015
Citation: 01002C
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/28/2018
Nr Instances: 1
Nr Exposed: 19
Related Event Code (REC): C
Gravity: 10
Report ID: 0316700
Contest Date:
Final Order: 07/26/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/26/2018 | $0.00 | Serious | ||
Penalty | Z: Issued | 06/28/2018 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 002C Hazard:
29 CFR 1910.184(e)(3)(ii): Records of the most recent month in which each alloy steel chain sling was thoroughly inspected were not available for examination: (a) PRODUCTION AREAS - Employees used an undetermined number of alloy steel chain devices to lift parts and equipment throughout the repair garage area and the new equipment production area, and the employer did not have records to indicate that the devices had been inspected, on or about February 15, 2018. No abatement certification or documentation required.