Violation Detail
Standard Cited: 19100134 D03 III B 2 Respiratory Protection.
Inspection Nr: 1278719.015
Citation: 01002C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/14/2018
Nr Instances: 1
Nr Exposed: 8
Abatement Date: 01/10/2019
Gravity: 5
Report ID: 0112000
Contest Date: 06/06/2018
Final Order: 12/26/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 12/26/2018 | $0.00 | 01/10/2019 | Serious | |
Penalty | C: Contested | 06/11/2018 | $0.00 | 06/29/2018 | Serious | |
Penalty | Z: Issued | 05/14/2018 | $0.00 | 06/29/2018 | Serious |
Text For Citation: 01 Item/Group: 002C Hazard:
29 CFR 1910.134(d)(3)(iii)(B)(2): The employer did not implement a change schedule for respirators not equipped with an End of Service Life Indicator that would ensure cartridges were changed before the end of their service life Clean room; On or about 2/2/18, the employer did not provide a change schedule for PAPR respirators used for the hazards of using Peridox. Peridox is a cleaning chemical containing hydrogen peroxide and peracetic acid, to sanitize the clean room. Inhalation can cause respiratory irritation, shortness of breath and mucous/fluid in the respiratory tract and lungs. The manner and quantity in which the material is used has resulted in an overexposure at a level that is four times the permissible exposure level of 1.4 mg/m3.