Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1275665.015
Citation: 01002C
Citation Type: Serious
Abatement Date: 03/22/2018 7
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/19/2017
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC): R
Gravity: 10
Report ID: 0112600
Contest Date:
Final Order: 01/18/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 12/19/2017 | $0.00 | 03/22/2018 | Serious |
Text For Citation: 01 Item/Group: 002C Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: Foley Transportation, 235 Taylor St., Springfield, Massachusetts; On and before November 8, 2017, the employer did not train employees on the purpose and function of the energy control program.