Violation Detail
Standard Cited: 19100134 K01 Respiratory Protection.
Inspection Nr: 1234830.015
Citation: 01002C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 11/17/2017
Nr Instances: 2
Nr Exposed: 2
Abatement Date: 07/15/2019
Gravity: 5
Report ID: 0213100
Contest Date: 12/13/2017
Final Order: 06/14/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 06/14/2019 | $0.00 | 07/15/2019 | Serious | |
Penalty | C: Contested | 01/05/2018 | $0.00 | 01/08/2018 | Serious | |
Penalty | Z: Issued | 11/17/2017 | $0.00 | 01/08/2018 | Serious |
Text For Citation: 01 Item/Group: 002C Hazard:
29 CFR 1910.134(k)(1): The employer did not provide effective training to ensure that each employee could demonstrate knowledge of 1910.134(k)(1)(i) - (vii): (a) On or about 24 May 2017, in the mixing room where employees are required by the employer to wear tight fitting half face respirator while air chiseling dried concrete in the cement mixer. The employer did not provide effective training to ensure that each employee could demonstrate knowledge of 1910.134(k)(1)(i) - (vii).