Violation Detail
Standard Cited: 19260502 F02 II Fall protection systems criteria and practices.
Inspection Nr: 1217498.015
Citation: 01002C
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/23/2017
Nr Instances: 2
Nr Exposed: 7
Abatement Date:
Gravity: 5
Report ID: 0936200
Contest Date:
Final Order: 04/17/2017
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/17/2017 | $0.00 | Serious | ||
Penalty | Z: Issued | 03/23/2017 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 002C Hazard:
29 CFR 1926.502(f)(2)(ii): The rope, wire, or chain was not rigged or supported in such a way that its lowest point (including sag) was not less than 34 inches (0.9 m) from the walking/working surface and its highest point no more than 39 inches (1.0 m) from the walking/working surface. a) Location: Southwest roof corner of South Commissary Project, 20850 Vandegrift Boulevard, MCB Camp Pendleton, CA. Warning lines were sagging to a height of 21.75 inches from the working surface. Employees were not protected from falling 23 feet to the lower level while performing roofing work activities. b) Location: Eastern wall on roof of South Commissary Project, 20850 Vandegrift Boulevard, MCB Camp Pendleton, CA. Warning lines were lying on the working surface. Employees were not protected from falling 23 feet to the lower level while accessing the roof and performing roofing activities.