Violation Detail
Standard Cited: 19100147 C06 II The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1210687.015
Citation: 01002C
Citation Type: Serious
Abatement Date: 05/12/2017 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/02/2017
Nr Instances: 1
Nr Exposed: 23
Related Event Code (REC):
Gravity: 10
Report ID: 0522500
Contest Date: 05/26/2017
Final Order: 02/15/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 02/15/2018 | $0.00 | 05/12/2017 | Serious | |
Penalty | C: Contested | 06/02/2017 | $0.00 | 05/12/2017 | Serious | |
Penalty | Z: Issued | 05/02/2017 | $0.00 | 05/12/2017 | Serious |
Text For Citation: 01 Item/Group: 002C Hazard:
29 CFR 1910.147(c)(6)(ii): The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection.\ a. Located at the workplace: the employer did not certify any periodic inspections performed of the Slitter 1 lockout procedure.