Violation Detail
Standard Cited: 19100106 E06 II Flammable liquids.
Inspection Nr: 996386.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/03/2015
Nr Instances: 3
Nr Exposed: 6
Abatement Date: 03/11/2015
Gravity: 5
Report ID: 0215800
Contest Date: 03/20/2015
Final Order: 03/31/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 03/31/2016 | $0.00 | 03/11/2015 | Serious | |
Penalty | C: Contested | 03/25/2015 | $0.00 | 03/11/2015 | Serious | |
Penalty | Z: Issued | 03/03/2015 | $0.00 | 03/11/2015 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
9 CFR 1910.106(e)(6)(ii): Class I flammable liquid(s) were dispensed into containers without electrically interconnecting the nozzle and the container: a) Finishing/Decorating Room, on or about 9/19/14: Employee dispensed a flammable material, Glassclad 18 from 5 gallon container to a secondary container with no means of electrically interconnecting the nozzle and the portable container. b) Media Lab, on or about 10/2/14: Employee dispensed flammable material, OptiClear R from a 5 gallon container to a secondary container with no means of electrically interconnecting the nozzle and the portable container. c) Screen Cleaning Room, on or about 10/21/14: Employee dispensed a flammable material, OptiClear R from a 5 gallon container to a secondary container with no means of electrically interconnecting the nozzle and the portable container.