Violation Detail
Standard Cited: 19100134 I07 Respiratory Protection.
Inspection Nr: 992599.015
Citation: 01002B
Citation Type: Other
Abatement Date: 02/24/2015 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 02/20/2015
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC): C
Gravity:
Report ID: 0627700
Contest Date:
Final Order: 03/16/2015
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/16/2015 | $0.00 | 02/24/2015 | Other | |
Penalty | Z: Issued | 02/20/2015 | $0.00 | 02/24/2015 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.134(i)(7): Oil lubricated compressor(s) used to supply breathing air did not have a high-temperature or carbon monoxide alarm(s) or both: On or about August 28, 2014, a high temperature alarm or/and a carbon monoxide alarm were not provided on an oil-lubricated air compressor that supplied breathing air to a Clemco Apollo 600 HP supplied air abrasive blasting respirator worn by employees during abrasive blasting activities. Employees were using blast media containing crystalline silica and were exposed to gas, vapor, and dust hazards.