Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 981357.015
Citation: 01002B
Citation Type: Serious
Abatement Status:
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/08/2014
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 01/27/2015
Gravity: 5
Report ID: 0729300
Contest Date: 01/02/2015
Final Order: 12/10/2015
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 12/10/2015 | $0.00 | 01/27/2015 | Serious | |
| Penalty | C: Contested | 01/02/2015 | $0.00 | 01/27/2015 | Serious | |
| Penalty | Z: Issued | 12/08/2014 | $0.00 | 01/27/2015 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented, and utilized for the control of potentially hazardous energy when employee(s) were engaged in activities covered by this section: a/ Inside of the Maintenance Bay, written procedures were not developed or documented for the control of potentially hazardous energy belonging to machinery such as, but not limited to, the John Deere Trackhoe, m/n 892ELC, s/n FF892BX011179. The hazardous energy sources include but are not limited to electrical residual energy and gravity.