Violation Detail
Standard Cited: 19100179 N04 I Overhead and gantry cranes.
This violation item has been deleted.
Inspection Nr: 976253.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/04/2014
Nr Instances: 3
Nr Exposed: 6
Abatement Date: 06/12/2014
Gravity: 10
Report ID: 0420100
Contest Date:
Final Order: 06/30/2014
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/30/2014 | $0.00 | 06/12/2014 | Serious | |
| Penalty | Z: Issued | 06/04/2014 | $0.00 | 06/12/2014 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.179(n)(4)(i): The upper limit switch of each hoist was not tried out under no load, at the beginning of each operator's shift: a) Unit 3 Turbine Housing Unit - On or about 5/7/14. employees were exposed to struck-by and crushing hazards when the limit switch was not tested at the beginning of the shift. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Translate