Violation Detail
Standard Cited: 19260502 I03 Fall protection systems criteria and practices.
Inspection Nr: 960310.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/27/2014
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 5
Report ID: 0215000
Contest Date: 07/22/2014
Final Order: 12/01/2014
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 12/01/2014 | $0.00 | Serious | ||
Penalty | C: Contested | 07/22/2014 | $0.00 | Serious | ||
Penalty | Z: Issued | 05/27/2014 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1926.502(i)(3): All floor hole covers were not secured when installed so as to prevent accidental displacement by wind, equipment, or employees: a) A plywood floor hole cover on the 3fl was not secured during concrete construction; employees can fall 10 feet or step into the 2 ft wide hole if the cover shifts. The cover was cut to the exact size as the floor hole so can collapse if displaced (shifted) one inch. Location: 81 Fleet Place, Brooklyn, N.Y; construction worksite. On or about 2/24/2014 NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.