Violation Detail
Standard Cited: 19100212 A01 General requirements for all machines.
Inspection Nr: 943256.015
Citation: 01002B
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/10/2014
Nr Instances: 5
Nr Exposed: 3
Related Event Code (REC):
Gravity: 10
Report ID: 0418400
Contest Date:
Final Order: 05/23/2014
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/23/2014 | $0.00 | Serious | ||
Penalty | Z: Issued | 04/10/2014 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Maintenance Shop on or about February 05, 2014, the DoAll band saw did not have the unused portion of the blade guarded, exposing employees to an amputation hazard. b) Maintenance Shop on or about February 05, 2014, the Cincinnati Gilbert Milling Machine was not provided with a guard to cover the rotating drill, exposing employees to hazards of the rotating chuck and flying chips. c) Maintenance Shop on or about February 05, 2014, the Lagun Milling Machine was not provided with a guard to cover the rotating drill, exposing employees to hazards of the rotating chuck and flying chips. d) Maintenance Shop on or about February 05, 2014, the Cincinnati Milacron Milling Machine was not provided with a guard to cover the rotating drill, exposing employees to hazards of the rotating chuck and flying chips. e) Maintenance Shop on or about February 05, 2014, the Cincinnati Milling Machine was not provided with a guard to cover the rotating drill, exposing employees to hazards of the rotating chuck and flying chips. ABATEMENT CERTIFICATION IS NOT REQUIRED