Violation Detail
Standard Cited: 19100179 J03 Overhead and gantry cranes.
Inspection Nr: 546919.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 11/30/2012
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 12/17/2012
Gravity: 10
Report ID: 0626700
Contest Date:
Final Order: 12/26/2012
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 11/30/2012 | $0.00 | 12/17/2012 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR1910.179 (j)(3) :The items listed in subparagraphs (j)(3)(i) (j)(3)(x) were not inspected for defects at intervals as defined in paragraph(j)(1)(ii) of this section or as specifically indicated, and all deficiencies were not carefully examined and a determination made as to whether they constituted a safety hazard. On July 30, 2012, in the slab yard crane # 4 the employer did not sure that employees were correctly conducting periodic inspections, exposing employees to stuck-by hazards.