Violation Detail
Standard Cited: 19100146 D05 I Permit-required confined spaces
Inspection Nr: 415682.015
Citation: 01002B
Citation Type: Serious
Abatement Date: 11/02/2012 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 11/01/2012
Nr Instances: 2
Nr Exposed: 2
Related Event Code (REC): C
Gravity: 10
Report ID: 0521700
Contest Date:
Final Order: 11/20/2012
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/20/2012 | $0.00 | 11/02/2012 | Serious | |
Penalty | Z: Issued | 11/01/2012 | $0.00 | 11/02/2012 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.146(d)(5)(i): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not evaluate permit space conditions when entry operations were conducted by testing conditions in the permit space to determine if acceptable entry conditions existed before entry was authorized to begin: a. On or about May 3, 2012, in the facility, employees were required to enter permit required confined space(s). The employee(s) did not evaluate permit space conditions by testing the permit space with a hazardous gas meter to ensure that the space was safe for entry.