Powered by GoogleTranslate

Violation Detail

Standard Cited: 5A0001 OSH Act General Duty Paragraph

Inspection Nr: 307596429

Citation: 01002B

Citation Type: Serious

Abatement Status: X

Initial Penalty:

Current Penalty:

Issuance Date: 12/08/2004

Nr Instances: 1

Nr Exposed: 28

Abatement Date: 01/05/2005

Gravity: 03

Report ID: 0625700

Contest Date:

Final Order:

Related Event Code (REC): C

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty I: Informal Settlement 12/21/2004 01/05/2005 Serious  
Penalty Z: Issued 12/08/2004 01/05/2005 Serious  

Text For Citation: 01 Item/Group: 002B Hazard: FALLING

Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish to each of his employees a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of: a) For the period of time up to and including 23 Aug 04, the employer did not always ensure that the #7 Paper Machine Freight Elevator was properly inspected and tested in accordance with the requirements set forth in ASME A17.1-1996, "Safety Code for Elevators & Escalators". According to Section 1001, "Routine Inspection and Tests of Passenger and Freight Electric Elevators" Rule 1001.1 of the above referenced ASME standard, "Inspection and Test Periods", it states that "The routine inspections and tests of passenger and freight electric elevators shall be made at intervals not longer than 6 months". The inspections and tests requirements are set in Rule 1001.2. According to Section 1002, "Periodic Inspection and Tests of Passenger and Freight Electric Elevators" Rule 1002.1 of the above referenced ASME standard, "Inspection and Test Periods", it states that "In addition to the routine inspection and tests (Rule 1001.2), the inspections and tests specified in Rule 1002.2, "1 year Inspection and Test Requirements", shall be performed at intervals not longer than 1 year, and the inspections and tests specified in Rule 1002.3, "5 year Inspection and Test Requirements", shall be made at intervals not longer than 5 years." This condition exposed employees to the hazards and injuries related to the failure of the various elevator car safety devices, interlocks, controls and operating circuits, which may result in the sudden and unexpected fall of the car itself, a distance of 25-30 ft. Among other methods, one feasible and acceptable abatement method to correct this hazard would be to: 1. Properly conduct elevator inspections and tests as required by the ASME standards by individuals authorized to conduct such inspections and tests as defined in Rule 1000.1 and subsequent sections. DISCLAIMERS: 1) You are not limited to the abatement methods suggested above. 2) The methods explained are general and may not be effective in all cases. 3) The employer is responsible for selecting and carrying out an appropriate method.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.