Violation Detail
Standard Cited: 19260652 G01 II Requirements for protective systems.
Inspection Nr: 1835224.015
Citation: 01002B
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/10/2025
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 01/16/2026
Gravity: 10
Report ID: 0830600
Contest Date:
Final Order: 01/02/2026
Related Event Code (REC): I
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/02/2026 | $0.00 | 01/16/2026 | Other | |
| Penalty | Z: Issued | 12/10/2025 | $0.00 | 01/16/2026 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1926.652(g)(1)(ii): Shields were not installed in a manner to restrict lateral or other hazardous movement of the shield in the event of the application of sudden lateral loads: (a) Jackson Creek Parkway & CO 105: On or about July 2, 2025, the employer did not ensure that each employee removing a pipe inside the excavation was protected from struck-by hazards from hazardous movement of the shield. The aluminum shield [Model 66-4SWLE] was not installed so as to prevent lateral loads from compromising the protective capacity of the shield system, in that it was installed so that gaps of more than 3 feet existed between the shield and the excavation walls.