Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1811188.015
Citation: 01002B
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $10,641.00
Current Penalty: $0.00
Issuance Date: 05/06/2025
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 06/02/2025
Gravity: 5
Report ID: 0317300
Contest Date:
Final Order: 05/30/2025
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/30/2025 | $0.00 | 06/02/2025 | Other | |
Penalty | Z: Issued | 05/06/2025 | $10,641.00 | 06/02/2025 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: a) 1601 POW/MIA Parkway Dover Delaware 19904 (Macarbox line): On or about March 17, 2025, and days prior thereto, employees conducting service/maintenance were not protected from caught-in injuries as a result of not following the established lockout tagout procedure.