Violation Detail
Standard Cited: 19100147 C07 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1783370.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/18/2025
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 05/14/2025
Gravity: 5
Report ID: 0627700
Contest Date:
Final Order: 05/06/2025
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/06/2025 | $0.00 | 05/14/2025 | Serious | |
Penalty | Z: Issued | 04/18/2025 | $0.00 | 05/14/2025 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. On or about October 18, 2024 and at times prior thereto, on the east side of the warehouse, employees perform modifications and maintenance on the preexpander and DWS hopper and have not recieved adequate energy control training.