Violation Detail
Standard Cited: 19100212 A01 General requirements for all machines.
Inspection Nr: 1780407.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 02/27/2025
Nr Instances: 2
Nr Exposed: 3
Abatement Date: 04/04/2025
Gravity: 10
Report ID: 0728900
Contest Date:
Final Order: 03/12/2025
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/12/2025 | $0.00 | 04/04/2025 | Serious | |
Penalty | Z: Issued | 02/27/2025 | $0.00 | 03/19/2025 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about October 2, 2024, it was documented that employees engaged in pretensioning activities at Coreslab Structures (Omaha) Inc. located at 802 Alliance Road, Bellevue, Nebraska were exposed to caught-in hazards in that the employer did not ensure the hydraulic jacking ram was guarded to protect employees and prevent them from placing body parts into the hydraulic ram during operation. Instances included, but were not limited to: i. Daily operations in building 1 where employees perform initial pretensioning to approximately 3,000 pounds per square inch and ii. Daily operations in building 2 where employees perform Initial pretensioning to approximately 3,000 pounds per square inch.