Violation Detail
Standard Cited: 19100333 C03 I A 1 Selection and use of work practices
Inspection Nr: 1765328.015
Citation: 01002B
Citation Type: Serious
Abatement Date: 02/25/2025
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 01/29/2025
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): A
Gravity: 10
Report ID: 0420600
Contest Date: 02/21/2025
Final Order:
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | C: Contested | 03/05/2025 | $0.00 | 02/25/2025 | Serious | |
Penalty | Z: Issued | 01/29/2025 | $0.00 | 02/25/2025 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.333(c)(3)(i)(A)(1): Unqualified employees working in an elevated position near overhead lines with voltages to ground rated at 50 kV or below and their conductive tools were not kept greater than 10-feet from from unguarded energized overhead lines: a)On or about July 30, 2024, in the front yard, an employee working from and maneuvering a NiftyLift aerial lift was exposed to an electrocution hazard in that, the lift with a Stihl pruner pole saw within 6 feet of an energized 7,200 volt unguarded overhead powerlines.