Violation Detail
Standard Cited: 19100217 D09 I Mechanical power presses.
Inspection Nr: 1762938.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/20/2024
Nr Instances: 2
Nr Exposed: 11
Abatement Date: 10/17/2024
Gravity: 5
Report ID: 0111500
Contest Date:
Final Order: 10/16/2024
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/16/2024 | $0.00 | 10/17/2024 | Serious | |
| Penalty | Z: Issued | 09/20/2024 | $0.00 | 10/17/2024 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.217(d)(9)(i): The employer did not establish a die setting procedure for mechanical power press(es) that would ensure compliance with 29 CFR 1910.217(c). Location - Establishment: On or about 07-11-24, the written die setting procedure did not instruct employees to lock out-tag out power presses prior to and during die set-up installations, adjustments, removal of punch holders, and die removal activities as per 1910.147.