Violation Detail
Standard Cited: 19100147 C06 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1748502.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/06/2024
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 12/02/2024
Gravity: 10
Report ID: 0522000
Contest Date:
Final Order: 09/25/2024
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/25/2024 | $0.00 | 12/02/2024 | Serious | |
Penalty | Z: Issued | 09/06/2024 | $0.00 | 10/02/2024 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.147(c)(6)(ii): The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection. a) On or about 05/08/2024, employer did not have an adequate certification of their periodic inspection for the machine specific procedures for the R2 01.20 feed compressor (Item number RL-PL2-11) located in the Plant 2 compressor building that identified all the employees included in the inspection, the person performing the periodic inspection to ensure that deviations such as not utilizing locks and chains on the three compressor valves were addressed.