Violation Detail
Standard Cited: 19100219 C04 II Mechanical power-transmission apparatus.
Inspection Nr: 1741254.015
Citation: 01002B
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/11/2024
Nr Instances: 1
Nr Exposed: 12
Abatement Date: 12/02/2024
Gravity: 5
Report ID: 0627100
Contest Date:
Final Order: 11/05/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/05/2024 | $0.00 | 12/02/2024 | Other | |
Penalty | Z: Issued | 10/11/2024 | $0.00 | 12/02/2024 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.219(c)(4)(ii): The unused keyway(s) of projecting shaft end(s) were not filled up or covered: (a) On or about April 15, 2024, in the packaging department, at the output freezer transition conveyer, employees were working next to a conveyor with exposed keyways.