Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1734021.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/01/2024
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 09/18/2024
Gravity: 10
Report ID: 0523400
Contest Date:
Final Order: 08/15/2024
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/15/2024 | $0.00 | 09/18/2024 | Serious | |
| Penalty | Z: Issued | 08/01/2024 | $0.00 | 09/18/2024 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (b) On or about March 12, 2024, the employer had not developed, documented and utilized machine specific procedures for, but not limited to the PRS Group Dismantler, Pallet Jig, and Pallet Stacker.
Translate