Violation Detail
Standard Cited: 19100147 D05 I The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1711402.015
Citation: 01002B
Citation Type: Serious
Abatement Status:
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/09/2024
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 06/05/2024
Gravity: 10
Report ID: 0627100
Contest Date:
Final Order: 06/06/2024
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/06/2024 | $0.00 | 06/05/2024 | Serious | |
| Penalty | Z: Issued | 05/09/2024 | $0.00 | 06/05/2024 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.147(d)(5)(i): All potentially hazardous stored or residual energy was not relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices: On or about November 12, 2023, in Plant #3, employees performed servicing and maintenance activities on equipment such as, but not limited to the Thiele Bag Placer, Serial #7138A110. Stored energy such as, but not limited to pneumatic energy was not relieved, disconnected, restrained, and otherwise rendered safe.