Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1692389.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 01/30/2024
Nr Instances: 4
Nr Exposed: 12
Abatement Date: 03/06/2024
Gravity: 10
Report ID: 0523900
Contest Date:
Final Order: 02/23/2024
Related Event Code (REC): A;R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 02/23/2024 | $0.00 | 03/06/2024 | Serious | |
| Penalty | Z: Issued | 01/30/2024 | $0.00 | 03/06/2024 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): (a) Coating room; On or about August 16, 2023, energy isolation devices were not used to control electric, pneumatic, and gravitational energy sources on the HST oven and related conveyor systems before an employee entered the machine enclosure to perform servicing and maintenance activities of troubleshooting the function of inlet side conveyor components. An employee's finger was partially amputated after being crushed by an exposed cylinder when it retracted to lower the inlet belt conveyor during production operations. (b) Coating room; On or about August 14, 2023, energy isolation devices were not used to control electric, pneumatic, and gravitational energy sources on the HST oven and related conveyor systems before four employees entered the machine enclosure to perform servicing and maintenance activities of manually cleaning debris from internal machine and conveyor belt surfaces. (c) Coating room; On or about August 14 through 16, 2023, energy isolation devices were not used to control electric, pneumatic, and gravitational energy sources on the HST oven and related conveyor systems before an employee entered the machine enclosure to perform servicing and maintenance activities of removing, cleaning, and replacing material stop pins on the inlet side conveyor system. (d) Coating room; On or about August 16 through August 18, 2023, energy isolation devices were not used to control electric, pneumatic, and gravitational energy sources on the HST oven and related conveyor systems before two employees entered the machine enclosure and knelt down to perform servicing and maintenance activities of tensioning bottom rack return conveyor belts.
Translate