Violation Detail
Standard Cited: 19100333 C07 Selection and use of work practices
Inspection Nr: 1691239.015
Citation: 01002B
Citation Type: Serious
Abatement Date: 02/26/2024 2
Initial Penalty: $11,292.00
Current Penalty: $0.00
Issuance Date: 01/30/2024
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): A
Gravity: 10
Report ID: 0625400
Contest Date:
Final Order: 02/14/2024
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/14/2024 | $0.00 | 02/26/2024 | Serious | |
Penalty | Z: Issued | 01/30/2024 | $11,292.00 | 02/26/2024 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.333(c)(7): Portable ladders did not have non conductive siderails if they were used where the employee or the ladder could contact exposed energized parts. On or about August 14, 2023, employees were performing tree-trimming operations near overhead power lines while using an aluminum extension ladder, exposing the employees to an electrical hazard.