Violation Detail
Standard Cited: 19100134 F02 Respiratory Protection.
Inspection Nr: 1685966.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Not Completed - Employer Out of Business
Initial Penalty: $11,292.00
Current Penalty: $0.00
Issuance Date: 01/24/2024
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 02/28/2024
Gravity: 10
Report ID: 0213100
Contest Date:
Final Order: 02/21/2024
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/21/2024 | $0.00 | 02/28/2024 | Serious | |
Penalty | Z: Issued | 01/24/2024 | $11,292.00 | 02/28/2024 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.134(f)(2): The employer did not ensure that employees using tight fitting face piece respirators pass an appropriate qualitative or quantitative fit test prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter. a) On or about August 30, 2023, at bagging production line, for the employees wearing a 3M Aura 9205+ N95 respirator while loading fertilizer. A line production employee was exposed to total dust at a time weighted average (TWA) of 39.18 mg/m3 while filling bags of soil, which is approximately 2.6 times the permissible exposure limit (PEL) for total dust of 15 mg/m3. The employees were not fit tested, either qualitatively or quantitatively, prior to being required to use this respirator by the employer.