Violation Detail
Standard Cited: 19100147 C07 I B The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1666889.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/27/2023
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 5
Report ID: 0215800
Contest Date:
Final Order: 11/03/2023
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/03/2023 | $0.00 | Serious | ||
Penalty | Z: Issued | 10/27/2023 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure: a) Seneca Dairy Systems, LLC, 3236 N Hoster Road #9594, Seneca Falls, NY 13148: On or about 8/7/2023 the employer did not instruct employees in the purpose and use of the energy control procedure while performing maintenance on the V&O Press, Press number 292, Serial number 75-150.