Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1666286.015
Citation: 01002B
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $1,128.00
Current Penalty: $0.00
Issuance Date: 07/14/2023
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 08/09/2023
Gravity:
Report ID: 0729700
Contest Date:
Final Order: 07/28/2023
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/28/2023 | $0.00 | 08/09/2023 | Other | |
Penalty | Z: Issued | 07/14/2023 | $1,128.00 | 08/09/2023 | Other |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: In the CNC Area, employee(s) engaged in daily machine shop activities were not provided with machine specific lockout / tagout procedures for an automated CNC machine the employer had for over a year, which could be used for the control of potentially hazardous energy. The automated CNC machine is as follows: 1. Make: Emmegi; Model: Phantomatic TS Star; Designation: Centrto Di Lavoro; Serial #: C124615.