Violation Detail
Standard Cited: 19100147 D04 I The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1635114.015
Citation: 01002B
Citation Type: Serious
Abatement Status:
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/17/2023
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 05/30/2023
Gravity: 10
Report ID: 0418600
Contest Date:
Final Order: 06/14/2023
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection | 
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/14/2023 | $0.00 | 05/30/2023 | Serious | |
| Penalty | Z: Issued | 05/17/2023 | $0.00 | 05/30/2023 | Serious | 
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.147(d)(4)(i):Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a) At Injection Well 2-2 McDavid Lands, Century FL; On November 18, 2022, employees were exposed to struck-by hazards when performing servicing activities such as, but not limited to, changing the skillets and rings in the piping and lockout or tagout devices were not affixed to each energy isolating device.
Translate