Violation Detail
Standard Cited: 19260502 D17 Fall protection systems criteria and practices.
Inspection Nr: 1611035.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Not Completed - Worksite Changed
Initial Penalty: $7,252.00
Current Penalty: $0.00
Issuance Date: 11/07/2022
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 11/18/2022
Gravity: 5
Report ID: 0521700
Contest Date:
Final Order: 11/30/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/30/2022 | $0.00 | 11/18/2022 | Serious | |
Penalty | Z: Issued | 11/07/2022 | $7,252.00 | 11/18/2022 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1926.502(d)(17):The attachment point of the body belt was not located in the center of the wearer's back. The attachment point of the body harness was not located in the center of the wearer's back near shoulder level, or above the wearer's head. a. On or about July 26, 2022, at the above addressed jobsite, an employee conducting commercial steel tubing installation operations was wearing a personal fall arrest system (PFAS) with the attachment point at the employee's back and also at the employee's front, thus the harness was being worn upside down, near their waistline, exposing the employee to fall hazards.