Violation Detail
Standard Cited: 19100178 M08 Powered industrial trucks.
Inspection Nr: 1586768.015
Citation: 01002B
Citation Type: Serious
Abatement Date: 09/30/2022 2
Initial Penalty: $2,486.00
Current Penalty: $0.00
Issuance Date: 07/25/2022
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 1
Report ID: 0111700
Contest Date:
Final Order: 08/11/2022
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/11/2022 | $0.00 | 09/30/2022 | Serious | |
Penalty | Z: Issued | 07/25/2022 | $2,486.00 | 08/04/2022 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.178(m)(8): There shall be sufficient headroom under overhead installations, lights, pipes, sprinkler system, etc: Location: Warehouse On or about March 28, 2022, the employer failed to ensure that there was sufficient headroom under glass fluorescent lighting while using the Yale lift truck, Model GLC050VXNVRE083, Serial No. A310V17621J to stack and unstack pallets of material. Employees were exposed to be struck by broken glass.