Violation Detail
Standard Cited: 19100147 D05 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1584736.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $14,502.00
Current Penalty: $0.00
Issuance Date: 05/02/2022
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 05/26/2022
Gravity: 10
Report ID: 0626300
Contest Date:
Final Order: 05/20/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/20/2022 | $0.00 | 05/26/2022 | Serious | |
Penalty | Z: Issued | 05/02/2022 | $14,502.00 | 05/26/2022 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.147(d)(5)(i): All potentially hazardous stored or residual energy was not relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices: (a) On or about March 21, 2022, while locking and tagging out the Lisec VSA-35/25 Fully Automated Applicator all potentially hazardous stored or residual energy was not relieved, disconnected, restrained, or otherwise rendered safe after the application of lockout and tagout devices to energy isolating devices exposing employees working on it to a struck-by hazard.