Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1581546.015
Citation: 01002B
Citation Type: Serious
Abatement Status:
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/26/2022
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 09/12/2022
Gravity: 10
Report ID: 0830500
Contest Date: 08/24/2022
Final Order: 01/19/2023
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 01/19/2023 | $0.00 | 09/12/2022 | Serious | |
| Penalty | C: Contested | 08/26/2022 | $0.00 | 09/12/2022 | Serious | |
| Penalty | Z: Issued | 07/26/2022 | $0.00 | 09/12/2022 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed: On March 3, 2022, the employer failed to ensure that periodic inspections of the company's energy control procedures were completed at least annually to ensure that any changes to the existing procedures and/or deficiencies were identified. The lack of inspections for lockout procedures applies to the following equipment: a) The lockout procedure for the pugmill was missing the following: the purpose and scope of the procedure, types and magnitude of the energy sources to be render safe, and the steps to take to ensure that lockout was successful prior to the start of work activities.