Violation Detail
Standard Cited: 19100212 A03 II General requirements for all machines.
Inspection Nr: 1579083.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/01/2022
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 08/11/2022
Gravity: 10
Report ID: 0626600
Contest Date:
Final Order: 08/17/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/17/2022 | $0.00 | 08/11/2022 | Serious | |
Penalty | Z: Issued | 08/01/2022 | $0.00 | 08/11/2022 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.212(a)(3)(ii):Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): On or about February 17, 2022, in the trim area, where an employee was exposed to a struck-by hazard when operating the Betenbender Hydraulic Press Brake without a point of operation guard.