Violation Detail
Standard Cited: 19101000 E Air contaminants.
This violation item has been deleted.
Inspection Nr: 1574145.015
Citation: 01002B
Citation Type: Serious
Abatement Status:
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/19/2022
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 11/30/2022
Gravity: 10
Report ID: 0524700
Contest Date: 08/02/2022
Final Order: 05/30/2023
Related Event Code (REC):
Emphasis:
Substance: 0731
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 05/30/2023 | $0.00 | 11/30/2022 | Serious | |
| Penalty | C: Contested | 08/03/2022 | $0.00 | 11/30/2022 | Serious | |
| Penalty | Z: Issued | 07/19/2022 | $0.00 | 11/30/2022 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d): On or about April 20, 2022, the employer did not implement engineering and work practice controls to reduce and maintain exposure to copper fume to or below the PEL in the South Foundry while employees were working around HM1 during the production of copper alloys. An employee was exposed to airborne concentration of copper fume at an 8-hour time weighted average of 0.297 milligrams per cubic meter of air.
Translate