Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1529760.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/25/2021
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 11/04/2021
Gravity: 5
Report ID: 0626700
Contest Date:
Final Order: 11/17/2021
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/17/2021 | $0.00 | 11/04/2021 | Serious | |
Penalty | Z: Issued | 10/25/2021 | $0.00 | 11/04/2021 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: a) On or about April 30, 2021, in the Production Building, the Shar System Model D758N Mixer/Dispenser was not turned off and shut down while employees cleaned the machine, exposing employees to caught-in hazards.