Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1515810.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/22/2021
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 08/17/2021
Gravity: 10
Report ID: 0418100
Contest Date: 08/13/2021
Final Order: 05/31/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 05/31/2022 | $0.00 | 08/17/2021 | Serious | |
Penalty | C: Contested | 08/24/2021 | $0.00 | 08/17/2021 | Serious | |
Penalty | Z: Issued | 07/22/2021 | $0.00 | 08/17/2021 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6). a - On or about January 23, 2021, at the worksite Foundation Food Group, Inc., located at 2076 Memorial Park Drive, Gainesville, GA, at Plant 4, at Line 4 freezer room, employees on the Line 4 liquid nitrogen Immersion/Spiral freezer were exposed to amputation and chemical hazards as the employer did not ensure authorized employees utilized lockout while servicing and maintaining equipment.