Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1513451.015
Citation: 01002B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/03/2021
Nr Instances: 1
Nr Exposed: 8
Abatement Date: 08/27/2021
Gravity: 10
Report ID: 0214500
Contest Date: 11/30/2021
Final Order: 10/20/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 10/20/2022 | $0.00 | 08/27/2021 | Serious | |
Penalty | C: Contested | 12/02/2021 | $0.00 | 08/27/2021 | Serious | |
Penalty | Z: Issued | 08/03/2021 | $0.00 | 08/27/2021 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:(a)(LOCATION)(IDENTIFY SPECIFIC OPERATIONS AND/OR CONDITIONS)(IDENTIFY MACHINERY OR EQUIPMENT)(THIS INCLUDES ENFORCEMENT OF PROCEDURES) a) Warehouse L3 Room: The employer did not develop detailed site specific procedural steps for shutting down the CVC Capper Machine prior to maintenance/servicing, to prevent unexpected release of stored energy, thus exposing employees to an accident, on or about 2/4/21.